Newest IVL catheter linked to improvements in efficiency, deliverability
Johnson & Johnson MedTech recently released its new Shockwave C2 Aero Fly intravascular lithotripsy (IVL) catheter, which was designed cut balloon inflation and treatment times in half. Cardiovascular Business spoke with an early adopter of the technology at TCT 2026 in San Diego.
Yousif Ahmad, MBBS, PhD, medical director of complex coronary intervention and associate professor of medicine at the University of California San Francisco (UCSF), said the new IVL technology has improved procedural efficiency also helped expand the number of patients who can be treated without requiring atherectomy.
"The most obvious thing that it enhances is the efficiency and speed of the procedures," Ahmad said. "You reduce the amount of time the patient is on the table, you get through the procedure quicker and you still have that same safety that you've always had with IVL."
Beyond workflow improvements, the faster pulse delivery can provide clinical benefits for patients who have difficulty tolerating prolonged balloon inflations. IVL balloon inflation temporarily restricts blood flow in the coronary arteries, potentially causing ischemia, particularly in patients with limited hemodynamic reserve, Ahmad explained.
Previously, physicians sometimes had to deliver only part of the intended energy before deflating the balloon in unstable patients. They would then continue with the rest of procedure. With the faster technology, operators can provide the full treatment more quickly, potentially improving patient tolerance.
"You get less ischemia, patients tolerate the procedure better, and you can still adequately treat them," he said.
Technology advances expand IVL use
Ahmad said successive improvements in coronary IVL technology have substantially expanded its clinical utility since the first-generation devices were introduced. Early iterations delivered 80 pulses per minute compared to 120 pulses in newer devices. This allows physicians to treat longer calcified lesions. Improvements in catheter deliverability, particularly with the Aero platform, have also made it easier to navigate tortuous coronary anatomy and reduced the need for atherectomy at Ahmad's center.
"The deliverability is really much, much better," he said.
While atherectomy remains an important tool in complex procedures, Ahmad emphasized that his team continues to use it frequently when clinically appropriate. He added that balloon-based calcium modification offers advantages over atherectomy.
"If we can treat a large portion of these patients with balloon-based therapy that's easy to use, that's safe, very reproducible, actually less operator-dependent in terms of the results that you achieve, I think that's a really good thing for our patients," he said.
Improved balloon rewrapping with the new catheter also allows operators to use the same catheter in multiple vessels, something that was more difficult with earlier devices. He said this can help cut procedure costs.